NameDescriptionSymptomRecommendation
Cluster's Disk Await HighThis alert indicates that a Warning alert was raised in Cohesity.Disk Await HighThis alert is triggered when the Cohesity Cluster detects high latencies on a disk.
Cluster's Product Model is IncompatibleThis alert indicates that a Warning alert was raised in Cohesity.Product Model Incompatible

Cluster's Proxy Server is UnreachableThis alert indicates that a Warning alert was raised in Cohesity.Proxy Server Unreachable

Cluster has Firmware IncompatibilitiesThis alert indicates that a Warning alert was raised in Cohesity.Firmware IncompatibleThis alert is triggered if any firmware version for any components in the Node is not supported.
Cluster's Raid has DegradedThis alert indicates that a Critical alert was raised in Cohesity.Raid DegradedThis alert is typically triggered when a boot SSD or NVME SSD is offline or has failed.
Cluster has Non Empty Unmounted DirectoryThis alert indicates that a Warning alert was raised in Cohesity.Non Empty Unmounted DirectoryThis alert can be caused by files and directories being written to the mount point or an internal error.
Cluster has VM Ware Mount FailureThis alert indicates that a Warning alert was raised in Cohesity.VM Ware Mount Failure

Cluster's Rhino UnhealthyThis alert indicates that a Warning alert was raised in Cohesity.Rhino Unhealthy

Cluster Skipped VM Volume IndexingThis alert indicates that a Warning alert was raised in Cohesity.VM Volume Indexing Skipped

Cluster Upgrade FailedThis alert indicates that a Critical alert was raised in Cohesity.Upgrade FailedAfter the Cohesity Cluster upgrade is initiated, if the first Node is unable to download the upgrade package and install, then the upgrade is marked as failed and aborted. Downloading the upgrade package may fail for a number of reasons, such as network failures, download checksum mismatch, or mismatched versions.
Cluster has New Upgrade Packages AvailableThis alert indicates that a Info alert was raised in Cohesity.New Upgrade Packages AvailableIf your Cohesity Cluster has automatic polling enabled, the Cluster raises this alert whenever Cohesity releases a new upgrade package and publishes it to the Cohesity cloud upgrade server.
Cluster has Time Service IssuesThis alert indicates that a Warning alert was raised in Cohesity.Time Service

This alert can be triggered by one of the following conditions:

  • The configured NTP server is invalid or down.
  • The configured NTP server only implements a subset of the NTP protocol.

NOTE: There are known time synchronization issues with Windows NTP servers and time.nist.gov.


Cluster has Upgraded SuccessfullyThis alert indicates that a Info alert was raised in Cohesity.Upgrade Succeeded

Cluster Upgrade StartedThis alert indicates that a Info alert was raised in Cohesity.Upgrade StartedThis alert is triggered after an upgrade is initiated from the Cohesity Dashboard or the Cohesity CLI.
Cluster has Failed To Add A NodeThis alert indicates that a Warning alert was raised in Cohesity.Add Node Failed

Cluster's IPMI Is UnreachableThis alert indicates that a Info alert was raised in Cohesity.IPMI UnreachableThe IPMI username and password specified for the Node is different than the IPMI username and password specified in the configuration settings for the Cohesity Cluster. This can occur when the IPMI username and password were changed directly on the Node, not in the configuration settings for the Cohesity Cluster.
Cluster's Upgrade Is StuckThis alert indicates that a Warning alert was raised in Cohesity.Upgrade Stuck

Cluster has Service Versions MismatchedThis alert indicates that a Info alert was raised in Cohesity.Service Versions MismatchedThis alert is triggered if any two Nodes are running different versions of the same Cohesity service.
Cluster has Unexpected Virtual Appliance ResourcesThis alert indicates that a Info alert was raised in Cohesity.Virtual Appliance Resources Unexpected

Cluster has Service Gflags SetThis alert indicates that a Info alert was raised in Cohesity.Cluster Service Gflags Found

Cluster's View Box Space Usage HighThis alert indicates that a Critical alert was raised in Cohesity.View Box Space Usage HighThis alert is triggered when the Cohesity Cluster detects that a View Box is running out of space.
Cluster's Node Failure Is Not ToleratedThis alert indicates that a Info alert was raised in Cohesity.Node Failure Is Not ToleratedIf a Node in the Cohesity Cluster fails, its contents need to be copied to the other Nodes. If the Cohesity Cluster detects that the contents of a potentially failed Node cannot be copied to the remaining Nodes due a lack of disk space, this alert is triggered to indicate that Node failures cannot be tolerated.
Cluster has Disk OfflineThis alert indicates that a Critical alert was raised in Cohesity.Disk Offline

Cluster has Invalid StateThis alert indicates that a Critical alert was raised in Cohesity.Invalid StateThis alert should not occur under normal usage.
Cluster had a Kernel PanicThis alert indicates that a Critical alert was raised in Cohesity.Kernel Panic

Cluster Found New DiskThis alert indicates that a Info alert was raised in Cohesity.New Disk FoundThis alert is triggered if a disk is added to a Node or if a disk is replaced in a Node.
Cluster has Low Logs Disk SpaceThis alert indicates that a Info alert was raised in Cohesity.Logs Disk Space LowThis alert indicates that the Cohesity log rotation service may have crashed, is unable to keep up with the logging rate, or is unable to remove some large files.
Cluster has a Disk MissingThis alert indicates that a Warning alert was raised in Cohesity.Missing Disk

This alert can be caused by one of the following conditions:

  • The Cohesity Cluster was created with less disks than supported by the hardware model of the Node.
  • A Node with less disks than supported by hardware model of the Node is added to the Cohesity Cluster. The disk(s) may be pulled out or not completely inserted.

Cluster has Node Chassis ChangedThis alert indicates that a Warning alert was raised in Cohesity.Node Chassis ChangedThis alert may be triggered if a Node is moved from one chassis to another chassis.
Cluster has an Unexpected Bonding ModeThis alert indicates that a Info alert was raised in Cohesity.Bonding Mode Unexpected

This alert can be caused by one of the following conditions:

  • The bonding mode is changed directly on the bond interface of Node(s) but the bonding mode configured on the Cohesity Cluster is not updated.
  • The bonding mode configured on the Cohesity Cluster is changed but the bonding mode on the bond interface of a Node is not updated.

Cluster has an Unexpected MTUThis alert indicates that a Warning alert was raised in Cohesity.MTU Unexpected

This alert can be caused by one of the following conditions:

  • The MTU is changed directly on the bond interface of Node(s), and the MTU configured on the Cohesity Cluster is not updated.
  • The MTU configured on the Cohesity Cluster is changed, but the MTU on the bond interface of a Node is not updated.

Cluster has an Unexpected GatewayThis alert indicates that a Warning alert was raised in Cohesity.Gateway Unexpected

This alert can be caused by one of the following conditions:

  • The gateway is changed directly on the bond interface of Node(s), and the gateway configured on the Cohesity Cluster is not updated.
  • The gateway configured on the Cohesity Cluster is changed, but the gateway  on the bond interface of a Node is not updated.

Cluster has Disk Marked OfflineThis alert indicates that a Critical alert was raised in Cohesity.Disk Marked Offline

This alert can be caused by one of the following conditions:

  • Disk read/write fails with an error.
  • Disk read/write access is hung and does not complete in a reasonable time.

Cluster has Disk With Too Many Delta RecordsThis alert indicates that a Warning alert was raised in Cohesity.Disk With Too Many Delta Records

The clean up of the delta records is delayed due to the following conditions:

  • The NFS/SMB server process (called the Bridge) on the Cohesity Cluster is very busy.
  • The disks are very busy.

Cluster has Frequent Process RestartsThis alert indicates that a Warning alert was raised in Cohesity.Frequent Process Restarts

A process can restart for one or more of the following reasons:

  • An unexpected condition (assert) was encountered.
  • An operation within the process is hung, which triggered the failfast mechanism to restart the process.

Cluster Disk Is BadThis alert indicates that a Warning alert was raised in Cohesity.Disk Is BadThis alert is triggered when the disk is detecting read/write errors.
Cluster Node Is DownThis alert indicates that a Critical alert was raised in Cohesity.Node Is Down

Cluster has hit Write LimitThis alert indicates that a Critical alert was raised in Cohesity.Write LimitThe SSD is exceeding write thresholds, so it may need to be replaced soon.
Cluster has an IMPI EventThis alert indicates that a Warning alert was raised in Cohesity.Ipmi Event

Cluster has Uncorrectable ECC MemoryThis alert indicates that a Critical alert was raised in Cohesity.Mem Uncorrectable Ecc

Cluster has Correctable ECC MemoryThis alert indicates that a Warning alert was raised in Cohesity.Mem Correctable Ecc

Cluster's Watchdog TriggeredThis alert indicates that a Critical alert was raised in Cohesity.Watchdog Triggered

Cluster has Temp Out Of High RangeThis alert indicates that a Critical alert was raised in Cohesity.Temp Out Of High Range

Cluster has Temp Out Of Low RangeThis alert indicates that a Critical alert was raised in Cohesity.Temp Out Of Low Range

Cluster has Volt Out Of High RangeThis alert indicates that a Critical alert was raised in Cohesity.Volt Out Of High Range

Cluster has Volt Out Of Low RangeThis alert indicates that a Critical alert was raised in Cohesity.Volt Out Of Low Range

Cluster HDD RemovedThis alert indicates that a Critical alert was raised in Cohesity.Hdd Drive Removed

Cluster HDD FaultThis alert indicates that a Critical alert was raised in Cohesity.Hdd Drive Fault

Cluster has Power Supply RemovedThis alert indicates that a Critical alert was raised in Cohesity.Power Supply Removed

Cluster has Power Supply InsertedThis alert indicates that a Info alert was raised in Cohesity.Power Supply Inserted

Cluster Node RemovedThis alert indicates that a Critical alert was raised in Cohesity.Node Removed

Cluster Node InsertedThis alert indicates that a Info alert was raised in Cohesity.Node Inserted

Cluster Node Powered OffThis alert indicates that a Critical alert was raised in Cohesity.Node Powered Off

Cluster Node RebootedThis alert indicates that a Info alert was raised in Cohesity.Node Rebooted

Cluster Link Is UpThis alert indicates that a Info alert was raised in Cohesity.Link Is Up

Cluster Link Is DownThis alert indicates that a Info alert was raised in Cohesity.Link Is Down

Cluster has IPMI SEL ClearedThis alert indicates that a Info alert was raised in Cohesity.Ipmi Sel Cleared

Cluster has Thermal Trip TriggeredThis alert indicates that a Critical alert was raised in Cohesity.Thermal Trip TriggeredThis alert is triggered when the Node has detected a thermal issue, and the detected temperature is out of range.
Cluster has High Space UsageThis alert indicates that a Critical alert was raised in Cohesity.Cluster Space Usage HighThis alert is triggered when the Cohesity Cluster detects that it is running out of disk space.
Cluster has Hung Task ProgressThis alert indicates that a Warning alert was raised in Cohesity.Task Progress Hung

Cluster's Health AffectedThis alert indicates that a Warning alert was raised in Cohesity.Cluster Health

Cluster's Health AffectedThis alert indicates that a Info alert was raised in Cohesity.Cluster HealthA scan may not complete on schedule for many reasons. The issue may be benign and fix itself.
Cluster's Health AffectedThis alert indicates that a Warning alert was raised in Cohesity.Cluster Health

Cluster's Health AffectedThis alert indicates that a Warning alert was raised in Cohesity.Cluster Health

Cluster's Search Cluster Health AffectedThis alert indicates that a Critical alert was raised in Cohesity.Search Cluster Health

Cluster Search Node BusyThis alert indicates that a Warning alert was raised in Cohesity.Search Node Busy

This alert can be caused by the following conditions:

  • There is high load on elastic search.
  • The elastic search is consuming too much memory.

Cluster's Active Directory Not ReachableThis alert indicates that a Critical alert was raised in Cohesity.Active Directory Not Reachable

This alert can be caused by one of the following conditions:

  • The Active Directory server is down.
  • Incorrect network settings on the Cohesity Cluster.
  • Incorrect DNS settings on the Cohesity Cluster.

Cluster's Metadata Size Exceeds ThresholdThis alert indicates that a Critical alert was raised in Cohesity.Metadata Size Exceeds ThresholdContact Cohesity Support. Backup policies may need to be adjusted or more Nodes need to be added.
Cluster's Encryption Key CreatedThis alert indicates that a Info alert was raised in Cohesity.Encryption Key Created

Cluster's Key Rotation Policy ChangedThis alert indicates that a Info alert was raised in Cohesity.Key Rotation Policy Changed

Cluster has KMS CreatedThis alert indicates that a Info alert was raised in Cohesity.KMS Created

Cluster KMS DestroyedThis alert indicates that a Info alert was raised in Cohesity.KMS Destroyed

Cluster has Remote Replication Task StuckThis alert indicates that a Warning alert was raised in Cohesity.Remote Replication Task Stuck

Cluster had Remote Replication Task FailThis alert indicates that a Warning alert was raised in Cohesity.Remote Replication Task Failed

Cluster's Remote Replication File SkippedThis alert indicates that a Warning alert was raised in Cohesity.Remote Replication File Skipped

Cluster has Audit LogThis alert indicates that a Info alert was raised in Cohesity.Audit Log

External Target has Audit LogThis alert indicates that a Info alert was raised in Cohesity.Audit Log

Protection Job has Missing VM BackupThis alert indicates that a Critical alert was raised in Cohesity.Missing VM Backup

Protection Job's VM Cracking SkippedThis alert indicates that a Warning alert was raised in Cohesity.VM Cracking Skipped

This alert can be caused by the following conditions:

  • The Cohesity Cluster is not able to mount the VMDK.
  • The VM Snapshot has an issue.

Protection Job's Backup Job SucceededThis alert indicates that a Info alert was raised in Cohesity.Backup Job Succeeded

Protection Job's Backup Job FailedThis alert indicates that a Critical alert was raised in Cohesity.Backup Job Failed

A Job Run can fail for any of the following reasons:

  • There is an issue with primary environment such as a removed VM or a Snapshot failure.
  • The primary storage is full. (The primary storage contains the Objects that are backed up by the Cohesity Cluster.)
  • The Cohesity Agent is unreachable while attempting to back up physical servers.The storage on the Cohesity Cluster is full.

Protection Job's Backup Job SLA ViolatedThis alert indicates that a Warning alert was raised in Cohesity.Backup Job Sla Violated

A Job Run may take longer than the specified SLA for the following reasons:

  • If the primary storage is slow.
  • The network is slow.
  • The Cohesity Cluster is overloaded.
  • You specified SLA that is too short.

Protection Job Blackout Job Cancelled Blackout WindowThis alert indicates that a Warning alert was raised in Cohesity.Blackout Job Cancelled Blackout Window

Protection Job had Media Error During ArchivalThis alert indicates that a Critical alert was raised in Cohesity.Media Error During Archival

Protection Job had Media Error During RestoreThis alert indicates that a Critical alert was raised in Cohesity.Media Error During RestoreOne or more tapes that required to restore data are not available.
Protection Job had Integral Volume Reaching Max CapacityThis alert indicates that a Warning alert was raised in Cohesity.Integral Volume Reaching Max Capacity

Protection Job's Archive Job FailedThis alert indicates that a Warning alert was raised in Cohesity.Archive Job Failed

This alert can be caused by one of the following conditions:

  • When an Archive task fails due to some external target connectivity and/or credentials issues.
  • When an Archive task fails due to an internal Cohesity issue.

Protection Job's Archive Job StuckThis alert indicates that a Warning alert was raised in Cohesity.Archive Job Stuck

This alert can be caused by one of the following conditions:

  • When an Archive task doesn't make progress due to some external target connectivity and/or credentials issues.
  • When an Archive task doesn't make progress due to an internal Cohesity issue.

Protection Job's Restore Job StuckThis alert indicates that a Warning alert was raised in Cohesity.Restore Job Stuck

This alert can be caused by one of the following conditions:

  • When an Restore task doesn't make progress due to some external target connectivity and/or credentials issues.
  • When an Restore task doesn't make progress due to an internal Cohesity issue.

Protection Job's Restore Job FailedThis alert indicates that a Warning alert was raised in Cohesity.Restore Job Failed

This alert can be caused by one of the following conditions:

  • When a Restore task fails due to some external target connectivity and/or credentials issues.
  • When a Restore task fails due to an internal Cohesity issue.

Protection Job has Audit LogThis alert indicates that a Info alert was raised in Cohesity.Audit Log

Protection Policy has Audit LogThis alert indicates that a Info alert was raised in Cohesity.Audit Log

Protection Source has Audit LogThis alert indicates that a Info alert was raised in Cohesity.Audit Log

Restore Task has Audit LogThis alert indicates that a Info alert was raised in Cohesity.Audit Log

View has Audit LogThis alert indicates that a Info alert was raised in Cohesity.Audit Log

View Box has Audit LogThis alert indicates that a Info alert was raised in Cohesity.Audit Log

Cloud and Local Disk over 70 percent UsedThe cloud and local disks for this Cluster are over 70% used.Cloud and Local Disk Capacity over 70% Cloud and Local Disk Capacity under 80%Review the disk usage for this Cluster.
Local Disk over 70 percent UsedThe local disks for this Cluster are over 70% used.Local Disk Capacity over 70% and Local Disk Capacity less 80%Review the disk usage for this Cluster.


See also:

Metrics (Cohesity)